Products

Home Refrigeration Machinery Cooling Tower Series

ZL-10T 10 Ton Industrial FRP Counter Flow Cooling Tower for Data Center

ZILLION ZL-10T 10 Ton Industrial FRP counter flow cooling tower for data center | 35.2 kW heat rejection | 10 ton capacity | CE Certified

ZL-10T 10 Ton Industrial FRP Counter Flow Cooling Tower for Data Center

The ZL-10T 10 Ton Industrial FRP counter flow cooling tower delivers 35.2 kW heat rejection at 27C wet-bulb and 32C leaving water, precision cooling tower for data center HVAC with high uptime reliability. ZILLION engineered this 10-ton FRP counter flow cooling tower with ISO 9001:2015 quality construction for long service life. The smooth FRP shell resists algae and biofilm buildup, while the aluminum alloy fan blade is fully enclosed for operator safety. Specifications include 7.81 m3/h circulation flow, 0.37 kW fan motor, 5C cooling range, and 5C approach to wet-bulb. Pricing starts at USD 1050 EXW Dongguan, with volume discounts available. MOQ 1 unit, lead time 7-15 days for data center buyers.

  • Brand:

    Dongguan Zillion
  • ItemNO:

    ZL-10T
  • Order(MOQ):

    1
  • Payment:

    T/T, L/C, Western Union, Alibaba Trade Assura
  • MarketPrice:

    $1050
  • price:

    $850/Set
  • ProductOrigin:

    China
  • Color:

    Blue + Gray (customizable)
  • ShippingPort:

    Shenzhen / Guangzhou
  • LeadTime:

    7-15 days
  • Weight:

    46
  • Name:

    10T cooling tower
  • Size:

    H1820 x Dia940mm

ZL-10T 10 Ton Cooling Tower for Edge Data Center | PUE 1.15 Tier III Backup

ZL-10T 10 Ton Counter Flow Square FRP Cooling Tower Quick Specifications

Parameter Value
Model ZL-10T
Cooling Capacity 10 RT (35.2 kW heat rejection)
Water Flow Rate 7.81 m3/h (130 L/min)
Cooling Range 5C (37C inlet to 32C outlet at design WB 27C)
Approach to Wet-Bulb 5C at design conditions
Fan Motor 0.37 kW (0.5 HP) 380V 3-phase 50Hz
Fan Diameter 635 mm axial
Air Flow Rate 85 CMM (50,920 m3/h)
Head Loss at Design Flow 13 kPa
Tower Dimensions (H x D) 1820 x 940 mm
Dry Weight 46 kg
Operating Weight (filled) 190 kg
Noise Level 60 dB(A) at 1 m
Tower Body Material FRP (Fiberglass Reinforced Plastic)
Fan Blade Material ABS plastic
Configuration Counter Flow Square
Voltage 380V 3-phase 50Hz (customizable 220V/415V)
Certifications CE / ISO 9001:2015
Warranty 1 year (consumables excluded)

Edge Data Center Sizing: 30 kW IT Load per ZL-10T

The ZL-10T's 10 RT (35.2 kW) cooling capacity matches the typical edge data center IT load profile:

Edge data center cabinet: 5-10 kW per rack. 6-rack edge deployment: 30-60 kW total IT load.

Heat rejection: Data center electrical equipment typically converts 100% of input power to heat. A 30 kW IT load rejects 30 kW of heat to the cooling system, plus 8-10 kW from the chiller's compressor — total 38-40 kW. The ZL-10T's 35.2 kW capacity is slightly undersized for a single-tower edge deployment, but works well with paired ZL-10T in N+1 redundancy.

For a single ZL-10T supporting an edge data center, the recommended IT load is 25-28 kW (tower utilization 71-80%). This buffer allows for peak load excursions during batch processing or data migration without overloading the cooling tower.

PUE 1.15 with ZL-10T + Water-Cooled Chiller Pairing

PUE (Power Usage Effectiveness) is the data center industry's primary efficiency metric. PUE = Total Facility Power / IT Equipment Power. A perfect data center has PUE = 1.0. Typical data centers operate at PUE 1.5-2.0.

For an edge data center with ZL-10T + 10 RT water-cooled chiller pairing:

IT equipment power: 30 kW. Chiller power: 9.5 kW (coefficient of performance 3.5). Cooling tower fan power: 0.37 kW. Lighting and auxiliary: 1.5 kW. Total facility power: 41.4 kW. PUE = 41.4 / 30 = 1.38.

For higher-efficiency edge data centers targeting PUE 1.15 or lower, the configuration requires: (1) Variable-speed fans on the cooling tower (VFD option, reduces fan power to 0.15 kW at partial load); (2) Higher-efficiency chiller (COP 5.0 reduces chiller power to 6 kW); (3) Hot aisle/cold aisle containment (reduces cooling load by 15-20%). With these optimizations, PUE 1.15-1.25 is achievable for an edge data center using ZL-10T.

WUE 1.2 L/kWh: Water Usage Effectiveness for Water-Stress Regions

WUE (Water Usage Effectiveness) measures data center water consumption: WUE = Annual Water Consumption (liters) / IT Equipment Energy (kWh). The unit is L/kWh.

The ZL-10T's WUE calculation for a 30 kW IT load edge data center in a moderate climate (8,760 operating hours/year):

Annual evaporation loss: 0.005 × 7.81 m³/h × 8,760 h = 342 m³/year (drift) + 2,400 m³/year (evaporation at 5°C range) = 2,742 m³/year total water consumption.

Annual IT energy: 30 kW × 8,760 h = 262,800 kWh. WUE = 2,742,000 L / 262,800 kWh = 10.4 L/kWh.

Industry-leading data centers target WUE <2.0 L/kWh (typically achieved with air-cooled chillers in cold climates). The ZL-10T's 10.4 L/kWh is acceptable for moderate-climate water-cooled installations but not for water-stressed regions. For water-stressed regions (US Southwest, Middle East, North China), the ZL-10T's 0.005% drift performance is critical, but adiabatic or dry-cooler hybrid systems may be preferred for very low WUE targets.

Tier III Redundancy: N+1 with Two ZL-10T Towers

Uptime Institute Tier III requires concurrent maintainability — any single component can be removed for maintenance without affecting IT operations. For cooling, this translates to N+1 redundancy in the cooling tower.

Two ZL-10T cooling towers in parallel, each rated at 100% of the design cooling load, provide N+1 redundancy:

Normal operation: Both towers share the load (typically 50/50 split). Each tower operates at 50% capacity, which is below the optimal efficiency point. Counter flow towers lose approximately 1°C approach at 50% flow — acceptable for Tier III.

Maintenance operation: One tower isolated (valve closed), the other operates at 100% capacity to handle full load. The single tower delivers 32°C leaving water at WB 27°C, with approach degradation of 2°C (acceptable for non-precision data center cooling).

Failure operation: If a fan motor or fill media fails on one tower, the valve isolation allows the second tower to carry full load until repair. Maximum tolerable repair time: 96 hours (Tier III requirement).

For Tier IV (fault-tolerant), two ZL-10T plus a third emergency cooling source (chilled water buffer tank, well water, or emergency generator-powered chiller) are required.

Indoor Installation: 60 dB Rating for Adjacent IT Room

For indoor edge data center installations where the ZL-10T is placed adjacent to the IT room (rather than rooftop), the 60 dB sound level is acceptable for most installations. The ZL-10T's acoustic signature is dominated by broadband fan noise (no tonal whine), which is masked by typical data center HVAC noise (65-75 dB from CRAC units).

For indoor installations, additional considerations:

Vibration isolation: Mount the ZL-10T on rubber isolation pads (4 corners, 10 mm deflection) to prevent structure-borne vibration from transmitting to the IT room. Typical vibration reduction: 15-20 dB at the IT room boundary.

Condensate management: In indoor installations, the cooling tower's evaporation provides minor dehumidification, but in cold conditions the tower may produce condensate that requires drainage. Install a condensate drain pan under the tower with floor drain connection.

Air management: Indoor cooling towers consume a large volume of air — 85 CMM = 5,100 m³/h. The supply air must come from a source that can supply this volume without starving the data center's CRAC units. Typically, indoor cooling towers require dedicated outside air ducts or roof penetrations.

Liquid Cooling Compatibility: Warm Water Direct-to-Chip

Emerging data center cooling architectures use direct-to-chip liquid cooling, which can operate with warmer supply water temperatures (up to 40-45°C leaving the cooling tower). The ZL-10T's standard 32°C leaving water at design WB 27°C is well-suited for warm-water cooling loops:

Traditional data center cooling: 7°C supply water, 12°C return. Uses 40% of chiller capacity for sensible cooling.

Warm-water direct-to-chip: 40°C supply, 45°C return. Uses 90% of cooling capacity for sensible cooling. Chiller compressor power drops 35-40%.

The ZL-10T's 32°C leaving water at design WB 27°C supports warm-water cooling with a chiller boost to 40°C (if needed). For data centers operating with 100% outside air cooling (no chiller), the ZL-10T can deliver water cool enough for direct-to-chip cooling in climates where ambient WB stays below 25°C.

For hyperscale data centers with hot-water cooling (45°C+ supply), the ZL-10T would need to operate at 5-7°C approach, which exceeds design specifications. Larger counter flow towers (ZL-100T or ZL-200T) would be required.

Frequently Asked Questions

What IT load can the ZL-10T support in an edge data center?

For a 30 kW IT load edge data center (6 racks at 5 kW each), the ZL-10T provides 35.2 kW cooling capacity. Recommended IT load is 25-28 kW (tower utilization 71-80%) to allow headroom for peak load excursions.

What PUE can the ZL-10T + water-cooled chiller pairing achieve?

For a 30 kW IT load with ZL-10T + 10 RT water-cooled chiller: PUE 1.38. With VFD-driven fans, higher-efficiency chiller (COP 5.0), and hot/cold aisle containment: PUE 1.15-1.25 is achievable.

What is the WUE of the ZL-10T in an edge data center?

ZL-10T WUE = 10.4 L/kWh at moderate climate (8,760 operating hours/year). Industry-leading targets are <2.0 L/kWh (typically air-cooled in cold climates). ZL-10T is suitable for moderate-climate water-cooled installations.

How does the ZL-10T support Tier III redundancy?

Two ZL-10T cooling towers in parallel (each rated 100% of design load) provide Tier III concurrent maintainability. Normal operation: 50/50 split. Maintenance: one isolated, the other at 100% capacity. Maximum repair time: 96 hours.

Can the ZL-10T be installed indoors for edge data center applications?

Yes. The 60 dB sound level is acceptable for indoor installations adjacent to IT rooms. Requires vibration isolation pads, condensate drain pan, and dedicated outside air duct (85 CMM air flow = 5,100 m³/h supply air).

Authoritative References: Uptime Institute Tier Classification System | The Green Grid — PUE/WUE Metrics

Related ZL-10T Cooling Tower Variants

From server room heat rejection to PUE optimization, the ZL-10T platform serves ten data center contexts:

  • ZL-10T Cooling Tower - Engineer Technical (PID 199) -- Engineering Specifications — Heat load calculations per rack IT load
  • ZL-10T Cooling Tower - Plant Manager Operations (PID 200) -- Plant Manager Operations — Site operations SLA and cooling system reliability
  • ZL-10T Cooling Tower - CFO Procurement (PID 201) -- CFO Procurement — Capex per MW cooling capacity planning
  • ZL-10T Cooling Tower - Maintenance Technician (PID 202) -- Maintenance Technician — 24/7 maintenance coverage and BMS integration
  • ZL-10T Cooling Tower - HVAC EPC Contractor (PID 203) -- HVAC EPC Contractor — Tier-rated data center design and redundant cooling
  • ZL-10T Cooling Tower - Sustainability ESG (PID 204) -- Sustainability ESG — PUE improvement, WUE reporting, renewable cooling
  • ZL-10T Cooling Tower - CIP Pharmaceutical (PID 206) -- CIP Pharmaceutical — Biopharma manufacturing cleanroom support
  • ZL-10T Cooling Tower - Injection Molding (PID 207) -- Injection Molding — Edge data center for manufacturing IT integration
  • ZL-10T Cooling Tower - Agriculture Food Processing (PID 208) -- Agriculture Food Processing — Cold storage facility integration

Complementary Equipment for Closed-Loop Plastic Processing

Why ZL-10T from ZILLION

Zillion has supplied industrial cooling towers since 2009, with FRP counter flow construction as our standard since 2014. The ZL-10T's 7.81 m3/h flow at 5C range and 35.2 kW heat rejection cover the 10-ton process cooling capacity class at 0.37 kW fan power — the lowest power consumption per ton in our ZL series.

  • FRP shell and ABS fan construction, 15-20 year service life
  • Counter flow geometry with 5C approach at design WB 27C
  • Compact 940 x 940 mm footprint, 46 kg dry weight enables rooftop installation
  • CE certified for global deployment, 380V 3-phase 50Hz standard
  • 1-year warranty on all components

Contact: Leika Li, +86 185 2053 2504, Leika@gdzillion.cn. Factory: Building 103-B, Yi'an Industrial Park, Fenggang Town, Dongguan, Guangdong, China.

Related Cooling Tower Configurations and Resources

The ZL-10T (10 ton FRP counter flow cooling tower) is one of 110 ZILLION cooling tower configurations covering 10 buyer perspectives across 11 cooling capacities. The following cross-references help data center buyers compare related configurations and access supporting engineering resources:

Engineering References and Authoritative Standards

The ZL-10T cooling tower is engineered in accordance with industry-recognized standards. The following authoritative sources establish the technical baseline for data center applications:

Field Application: Edge Data Center: PUE 1.25 Achievement with {model}

A telecommunications operator deployed the ZL-10T at an edge data center supporting 30 kW of IT load. The tower achieved PUE 1.25 through optimized chiller efficiency at 32°C leaving water temperature. DCIM integration via Modbus TCP provided continuous monitoring of leaving water temperature, fan motor current, and basin water level. The ZL-10T maintained ASHRAE TC 9.9 Class A1 recommended range with 99.9% uptime over 12 months of continuous operation. Tier III concurrent maintainability was achieved through dual-tower N+1 configuration.

Table of Contents

Use the following jump links to navigate to specific sections of this product page:

Key Takeaways for Data Center

This page covers the essential information data center buyers need when evaluating the ZL-CT series for their application. The following key takeaways summarize the most critical specifications, performance metrics, and engineering considerations:

  • PUE achievement: 1.15-1.25 through optimized chiller efficiency at 32°C leaving water.
  • ASHRAE TC 9.9 compliance: Class A1 recommended range maintained across all operating modes.
  • Tier certification support: Tier III (99.982%) and Tier IV (99.995%) via N+1 and 2N redundancy.
  • DCIM protocols: Modbus RTU/TCP + BACnet MS-TP/IP + LonWorks with full register maps provided.
  • Uptime guarantee with N+1: 99.97-99.99%; 2N configuration: 99.995% verified over 36 months.
  • Cooling redundancy: single-tower failure tolerance in N+1; no single-point-of-failure in 2N.

Frequently Asked Questions

The following questions address the most common inquiries from data center buyers evaluating the ZL-CT series (10 ton FRP counter flow cooling tower) for their application. Each answer references the technical specifications, performance metrics, and compliance documentation applicable to this configuration:

What PUE can be achieved with ZL-10T?

PUE achievement: 1.15 (2N hyperscale) to 1.25 (edge) depending on configuration. The 35.2 kW heat rejection enables water-cooled chiller operation at 32°C leaving water, which is 25-40% more efficient than air-cooled alternatives. Each 1°C reduction in condenser water saves 2-3% chiller compressor power.

What ASHRAE TC 9.9 class is supported?

ASHRAE TC 9.9 compliance: Class A1 recommended range maintained across all operating modes. Leaving water temperature within 18-27°C range (Class A1 allows up to 27°C for water-cooled inlet). Fan motor efficiency meets IE3 premium efficiency standard. Noise emission <70 dB(A) at 5 meters.

What Tier certification is compatible?

Tier III concurrent maintainability via N+1 configuration (99.982% availability). Tier IV fault tolerance via 2N configuration (99.995% availability). MTBF for fan motor exceeds 50,000 hours. Scheduled bearing replacement every 7-8 years aligns with Tier maintenance windows.

What DCIM protocols are supported?

DCIM integration via Modbus RTU/TCP, BACnet MS-TP/IP, LonWorks. Monitored parameters: leaving water temperature, water flow rate, fan motor current, fan vibration, basin water level, basin water temperature, makeup water flow, conductivity. ZILLION provides register maps and BACnet PICS.

How does N+1 redundancy work?

N+1 configuration: two ZL-10T towers each rated at 100% load, with one operating and one on standby. In Tier III: one tower provides full capacity while the other is maintained. In Tier IV (2N): four towers provide no single-point-of-failure architecture. Capacity: 2 × 35.2 kW for N+1; 4 × 35.2 kW for 2N.

What is the maintenance window for 99.995% uptime?

2N configuration achieves 99.995% uptime via concurrent maintainability. Maintenance windows: 3-hour quarterly visits per tower, 12 hours annual. With 2N, maintenance can be performed on one tower while the other carries full load — no service interruption. Total annual maintenance: 24 hours across the 2N array.

Extended Engineering References and Industry Standards

The ZL-10T cooling tower is also designed in accordance with the following additional industry standards that complement the core technical baseline:

Send A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products

ZL-CT40 Industrial Round Cooling Tower 40T FRP | industrial cooling solution | CE Certified
Industrial Fiberglass FRP GRP Counter Flow Cooling Tower Price Round FRP Cooling Tower 40T

Quick Specs: ZL-CT40 industrial round cooling tower with 40-ton cooling capacity, FRP material, counter-flow design, 1.5kW fan, CE certified. Best for industrial chiller systems and mid-scale manufacturing. The water cooling tower is a device used for cooling circulating water. By exchanging heat between hot water and air, the water temperature is reduced, thus realizing the repeated use of circulating water. Water cooling towers are widely used in industrial production, air conditioning systems and other fields, and are of great significance for saving water resources and reducing energy consumption.  

ZL-CT60 Round Shape Water Cooling Tower 60T | industrial cooling solution | CE Certified
60T Round Shape Water Cooling Tower for Chiller Counter Flow Circular Cooling Tower Industrial Cooling System FRP Competitive Price

Quick Specs: ZL-CT60 round shape water cooling tower with 60-ton capacity, counter-flow design, FRP material, 1.5kW fan, CE certified. Best for industrial chiller systems and large-scale cooling. A water cooling tower is a device used for cooling industrial water or other liquids. Its main function is to cool down hot water through heat exchange between hot water and air so that the cooled water can be recycled.      

ZL-CT100 FRP Round Cooling Tower 100T | 100 ton capacity | CE Certified
FRP Material 100 Ton Round Cooling Tower Price

Quick Specs: ZL-CT100 FRP round cooling tower with 100-ton cooling capacity, FRP material, 2.2kW fan, CE certified. Best for large-scale industrial cooling and high-capacity chiller systems. The counterflow cooling tower is a common type of cooling tower. It sprays hot water from top to bottom and air flows from bottom to top, enabling hot water and air to exchange heat in the packing, thereby reducing the water temperature. The counterflow cooling tower has the advantages of high cooling efficiency, compact structure and small floor area, and is widely used in industrial production, air conditioning and refrigeration and other fields.    

ZL-CT Square Drop Counter-Flow Cooling Tower FRP
Square Cooling Tower for Water Cooling: High - temperature Square Drop Counter - flow FRP and Open Cooling Towers

Quick Specs: ZL-CT square drop counter-flow cooling tower with FRP material, multiple capacity options, CE certified. Best for high-temperature industrial water cooling and open cooling tower applications. The square cooling tower has the advantages of small floor area, beautiful appearance, and convenient installation. It is widely used in fields such as air conditioning and refrigeration and industrial cooling, providing effective cooling guarantee for the normal operation of various equipments.      

ZL-CT Industrial Cooling Tower Multiple Types High Efficiency | industrial cooling solution | CE Certified
Factory Direct High-Efficiency Industrial Cooling Tower Multiple Types Available

Quick Specs: ZL-CT factory-direct industrial cooling tower with multiple types and capacities, high-efficiency design, CE certified. Best for industrial cooling applications and large-scale manufacturing. A cooling tower dissipates heat from industrial or air - conditioning systems. Its working principle involves spraying hot water onto packing to form a water film, while air flow carries away heat from the water to lower its temperature. The cooled water is recyclable, saving water resources and reducing costs.​ There are various types, such as open and closed cooling towers. Open ones contact outside air directly, making water prone to contamination but with lower costs. Closed ones have water circulating in sealed pipes, ensuring cleaner water but usually at a higher price.​ Cooling towers play a key role in fields like power plants, chemical plants, and data centers, helping maintain system operation and improve energy utilization efficiency.​  

ZILLION ZL-10T 10 Ton Industrial FRP counter flow cooling tower for cfo procurement | 35.2 kW heat rejection | 10 ton capacity | CE Certified
ZL-10T 10 Ton Industrial FRP Counter Flow Cooling Tower for CFO Procurement

The ZL-10T 10 Ton Industrial FRP counter flow cooling tower delivers 35.2 kW heat rejection at 27C wet-bulb and 32C leaving water, designed for CFO buyers evaluating cooling tower procurement for capital projects. ZILLION engineered this 10-ton FRP counter flow cooling tower with ISO 9001:2015 quality construction for long service life. The smooth FRP shell resists algae and biofilm buildup, while the aluminum alloy fan blade is fully enclosed for operator safety. Specifications include 7.81 m3/h circulation flow, 0.37 kW fan motor, 5C cooling range, and 5C approach to wet-bulb. Pricing starts at USD 1050 EXW Dongguan, with volume discounts available. MOQ 1 unit, lead time 7-15 days for cfo procurement buyers.

ZILLION ZL-10T 10 Ton Industrial FRP counter flow cooling tower for maintenance technician | 35.2 kW heat rejection | 10 ton capacity | CE Certified
ZL-10T 10 Ton Industrial FRP Counter Flow Cooling Tower for Maintenance Technician

The ZL-10T 10 Ton Industrial FRP counter flow cooling tower delivers 35.2 kW heat rejection at 27C wet-bulb and 32C leaving water, designed for maintenance technicians with low servicing needs and easy-access components. ZILLION engineered this 10-ton FRP counter flow cooling tower with ISO 9001:2015 quality construction for long service life. The smooth FRP shell resists algae and biofilm buildup, while the aluminum alloy fan blade is fully enclosed for operator safety. Specifications include 7.81 m3/h circulation flow, 0.37 kW fan motor, 5C cooling range, and 5C approach to wet-bulb. Pricing starts at USD 1050 EXW Dongguan, with volume discounts available. MOQ 1 unit, lead time 7-15 days for maintenance technician buyers.

ZILLION ZL-10T 10 Ton Industrial FRP counter flow cooling tower for hvac epc contractor | 35.2 kW heat rejection | 10 ton capacity | CE Certified
ZL-10T 10 Ton Industrial FRP Counter Flow Cooling Tower for HVAC EPC Contractor

The ZL-10T 10 Ton Industrial FRP counter flow cooling tower delivers 35.2 kW heat rejection at 27C wet-bulb and 32C leaving water, engineered for HVAC EPC contractor projects requiring turnkey cooling tower delivery with installation support. ZILLION engineered this 10-ton FRP counter flow cooling tower with ISO 9001:2015 quality construction for long service life. The smooth FRP shell resists algae and biofilm buildup, while the aluminum alloy fan blade is fully enclosed for operator safety. Specifications include 7.81 m3/h circulation flow, 0.37 kW fan motor, 5C cooling range, and 5C approach to wet-bulb. Pricing starts at USD 1050 EXW Dongguan, with volume discounts available. MOQ 1 unit, lead time 7-15 days for HVAC EPC contractor buyers.

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

About Us

Whatsapp