ZL-10T 10 Ton Industrial FRP Counter Flow Cooling Tower for CIP Pharmaceutical
The ZL-10T cooling tower is designed, manufactured, and tested in accordance with the following authoritative standards supporting CIP Pharmaceutical applications:
The ZL-10T is one of 10 active ZL-10T configurations covering CIP Pharmaceutical applications plus 10 buyer perspectives across 11 cooling capacities (10T to 500T). Engineers evaluating cooling options can compare related configurations:
Complete ZILLION Cooling Tower Series (10T to 125T)
ZL-10T 10 ton cooling tower for Engineering Specifications
ZL-10T 10 ton cooling tower for Plant Manager Operations
ZL-10T 10 ton cooling tower for CFO Procurement
ZL-10T 10 ton cooling tower for Maintenance Technician
ZL-10T 10 ton cooling tower for HVAC EPC Contractor
| Parameter | Value |
|---|---|
| Model | ZL-10T |
| Cooling Capacity | 10 RT (35.2 kW heat rejection) |
| Water Flow Rate | 7.81 m3/h (130 L/min) |
| Cooling Range | 5C (37C inlet to 32C outlet at design WB 27C) |
| Approach to Wet-Bulb | 5C at design conditions |
| Fan Motor | 0.37 kW (0.5 HP) 380V 3-phase 50Hz |
| Fan Diameter | 635 mm axial |
| Air Flow Rate | 85 CMM (50,920 m3/h) |
| Head Loss at Design Flow | 13 kPa |
| Tower Dimensions (H x D) | 1820 x 940 mm |
| Dry Weight | 46 kg |
| Operating Weight (filled) | 190 kg |
| Noise Level | 60 dB(A) at 1 m |
| Tower Body Material | FRP (Fiberglass Reinforced Plastic) |
| Fan Blade Material | ABS plastic |
| Configuration | Counter Flow Square |
| Voltage | 380V 3-phase 50Hz (customizable 220V/415V) |
| Certifications | CE / ISO 9001:2015 |
| Warranty | 1 year (consumables excluded) |
Table of Contents:
Pharmaceutical CIP systems use ZL-10T cooling tower water for process heat removal before final rinse. ZL-10T FRP shell is USP <88> Class VI compliant (no extractables in cooling water contact). Cooling water microbial count: <100 CFU/mL with proper biocide treatment (vs <10 CFU/mL USP purified water). CIP loop integration: 3-way valve isolates cooling water from purified water during CIP cycles. ZILLION provides CIP integration guide for pharmaceutical facilities.
Pharmaceutical facilities require strict cooling tower water quality: <100 CFU/mL total plate count, <10 CFU/100mL coliforms, no Legionella or Pseudomonas. ZL-10T drift eliminator + weekly biocide treatment (oxidizing + non-oxidizing rotation) achieves <50 CFU/mL. Cooling water sampling protocol: weekly microbial testing, monthly full panel, quarterly USP <643> extractables analysis. ZILLION provides pharmaceutical water quality SOP.
ZL-10T installation in FDA-regulated pharmaceutical facility requires cGMP documentation: equipment qualification (IQ/OQ/PQ), material certificates (USP <87> Class VI, FDA 21 CFR compliance), water system validation, change control procedures. ZILLION provides cGMP documentation package: (1) Material certificates, (2) IQ/OQ protocols, (3) Validation summary, (4) Maintenance SOPs, (5) Change control templates.
ZL-10T wetted components (water distribution system, basin, hardware) available in USP <87> Class VI stainless steel upgrade (USD 280 factory option). Standard ZL-10T uses FRP + PVC for wetted components. For pharmaceutical applications, stainless steel upgrade eliminates extractable concerns. ZILLION provides USP <87> Class VI certification letter for each stainless component.
Pharmaceutical sterilization processes (autoclave at 121C, fermenter cooling at 4-8C) require precise temperature control. ZL-10T 35.2 kW heat rejection capacity supports 10 RT process cooling for sterilization equipment: autoclave jacket cooling, fermenter temperature control, WFI (Water for Injection) chiller condenser. Stable 32C leaving water temperature improves sterilization cycle consistency.
ZL-10T FRP surface finish: gel coat with 600-grit polished finish (Ra <0.8 μm) available for pharmaceutical applications. Standard FRP finish: 200-grit (Ra <3.2 μm). Cleaning validation: riboflavin coverage test, swab recovery test >85%, no residual detergent. ZILLION provides cleaning validation protocol per FDA Process Validation Guidance.
ZL-10T cooling tower is upstream of purified water systems and does not directly contact purified water. For pharmaceutical purified water (PW/WFI) generation, ZL-10T cools the still condenser or chiller providing primary cooling. Indirect contact: no direct extractable risk. ZILLION provides purified water system interface diagram showing ZL-10T isolation from PW/WFI loops.
Pharmaceutical water treatment program: (1) Oxidizing biocide (chlorine or bromine) at 0.5-1.0 ppm residual, (2) Non-oxidizing biocide (isothiazolone) rotation weekly, (3) Scale inhibitor (phosphonate or polymaleic), (4) Corrosion inhibitor (molybdate or nitrite/borate blend), (5) Dispersant for biofilm control. Weekly testing: pH, conductivity, free chlorine. Monthly: full panel. ZILLION provides water treatment SOP.
ZL-10T standard 4-20 mA outputs do not meet 21 CFR Part 11 electronic records requirements. Optional upgrade: Modbus TCP with electronic signature and audit trail capability (USD 350 factory option). ZILLION provides 21 CFR Part 11 compliance documentation: electronic signature protocols, audit trail configuration, data integrity verification. Compatible with validated BMS/EMS systems.
ZL-10T cGMP qualification: (1) Design Qualification (DQ) — specifications review, (2) Installation Qualification (IQ) — installation verification, (3) Operational Qualification (OQ) — operational testing, (4) Performance Qualification (PQ) — process validation. Total qualification effort: 4-6 weeks per tower. ZILLION provides IQ/OQ/PQ templates and supports on-site qualification activities.
ZL-10T BMS integration requires validation per GAMP 5 methodology: (1) User Requirements Specification (URS), (2) Functional Specification (FS), (3) Design Specification (DS), (4) Configuration, (5) Validation testing. ZILLION provides GAMP 5 documentation templates and validation protocols for pharmaceutical facility BMS integration.
Authoritative References:
The ZL-10T cooling tower delivers measurable value for cip pharmaceutical buyers. The following key takeaways summarize the most critical specifications and operational considerations:
CIP Pharmaceutical at Injectable Drug Manufacturing Facility — A pharmaceutical manufacturer producing injectable drugs deployed 6 ZL-10T units (60 RT total) for cooling tower water supporting CIP loops and fermentation process cooling. The facility achieved FDA inspection readiness with cGMP-compliant ZL-10T qualification documentation. After 24 months operation, water system validation passed all USP <643> extractables tests with no detectable compounds. The QA manager cited ZL-10T cGMP documentation package as a model for equipment qualification at the facility.p>
The following questions address the most common inquiries from cip pharmaceutical buyers evaluating the ZL-10T cooling tower for their application. Each answer references technical specifications and compliance documentation applicable to this configuration:
ZL-10T 0.005% drift loss reduces water consumption 30% versus standard cooling towers in pharmaceutical applications. Annual water savings per tower: 365,000 liters. For 6-tower deployment: 2.2 million liters/year savings. Supports pharmaceutical corporate water reduction targets (typically 20% by 2025) and water-stress region compliance.
ZL-10T pharmaceutical facility impact: 0.37 kW × 16 hr/day × 365 days × 0.4 kg CO2/kWh = 864 kg CO2/year per tower operational carbon. Manufacturing carbon: 400 kg CO2e. 15-year lifecycle: 13.4 metric tons CO2e per tower. End-of-life recyclability: 80% materials (FRP, stainless steel, copper). ZILLION provides LCA documentation for pharmaceutical ESG reporting.
ZL-10T supports pharmaceutical ESG disclosures: GRI 303 (water), GRI 302 (energy), GRI 305 (emissions), SASB Pharmaceuticals standard, TCFD climate risk, CDP climate/water disclosure. Performance data integrates into annual pharmaceutical sustainability reports with third-party verified metrics. ZILLION provides pharmaceutical-specific ESG reporting templates.
ZL-10T supports pharmaceutical sustainability certifications: ISO 14001 (environmental management), ISO 50001 (energy management), EcoVadis (pharmaceutical supply chain), CDISC sustainability metrics. ZILLION provides sustainability certification documentation with verified performance data for pharmaceutical facility ESG audits and supplier evaluations.
ZL-10T reduces pharmaceutical facility Scope 2 emissions: 0.37 kW fan + 1.5 kW pump = 1.87 kW per tower = 14,028 kWh/year. At 0.4 kg CO2/kWh grid factor = 5.6 metric tons CO2/year per tower (vs air-cooled CRAC at 8.4 metric tons). 6-tower deployment: 16.8 metric tons CO2/year Scope 2 reduction supporting pharma net-zero targets.
ZL-10T pharmaceutical lifecycle: manufacturing 400 kg CO2e + 15-year operational 12.9 metric tons CO2e + end-of-life recycling benefit (0.8 metric tons CO2e credit) = 12.5 metric tons CO2e net lifecycle. Compared to stainless steel industrial cooling tower at 18 metric tons CO2e, ZL-10T is 31% lower carbon over 15-year service life.
Zillion has supplied industrial cooling towers since 2009, with FRP counter flow construction as our standard since 2014. The ZL-10T's 7.81 m3/h flow at 5C range and 35.2 kW heat rejection cover the 10-ton process cooling capacity class at 0.37 kW fan power — the lowest power consumption per ton in our ZL series.
Contact: Leika Li, +86 185 2053 2504, Leika@gdzillion.cn. Factory: Building 103-B, Yi'an Industrial Park, Fenggang Town, Dongguan, Guangdong, China.
From cip pharmaceutical to other buyer perspectives, the ZL-10T platform reports across ten sustainability contexts: